Re: updated legacy mainframe app

From: David M. Zendzian (dmz_at_dmzs.com)
Date: 10/25/05

  • Next message: Talisker: "RE: Scanning Class A network"
    Date: Tue, 25 Oct 2005 09:13:25 -0700
    To: Gus Fritschie <gfritschie@hotmail.com>
    
    

    Think of it this way, what ever programming problems you put in front of
    your mainframe will expose your mainframe. So if .net or the code
    running in .net have bad code (input validation not checked, ...) then
    that will pass directly back to the mainframe and all of the controls on
    the mainframe will be bypassed because of the trust it will have with
    the frontend app.

    The application control tests (i hope you mean within the code and
    externally through code review) will help a lot with your concerns,
    however since you can't control the code for .NET & AG communicator you
    should assume you can't trust anything going to-from those environments.

    Good luck!
    dmz

    Gus Fritschie wrote:

    > Our organization is updating a legacy mainframe application to a GUI
    > client-server application. On the mainframe EntireX Broker will be
    > installed. The client software will include the following:
    >
    > 1) Microsoft .NET
    > 2) Software AG Communicator run time
    > 3) Compiled .NET code, dynamic link libraries, and EntireX client
    >
    > My question is what control weaknesses could be introduced by this
    > change and what tests would you recommend performing, besides basic
    > application control tests.
    >
    > Thanks!
    >
    >
    >
    > ------------------------------------------------------------------------------
    >
    > Audit your website security with Acunetix Web Vulnerability Scanner:
    > Hackers are concentrating their efforts on attacking applications on
    > your website. Up to 75% of cyber attacks are launched on shopping
    > carts, forms, login pages, dynamic content etc. Firewalls, SSL and
    > locked-down servers are futile against web application hacking. Check
    > your website for vulnerabilities to SQL injection, Cross site
    > scripting and other web attacks before hackers do! Download Trial at:
    >
    > http://www.securityfocus.com/sponsor/pen-test_050831
    > -------------------------------------------------------------------------------
    >
    >
    >
    >
    >
    >

    ------------------------------------------------------------------------------
    Audit your website security with Acunetix Web Vulnerability Scanner:

    Hackers are concentrating their efforts on attacking applications on your
    website. Up to 75% of cyber attacks are launched on shopping carts, forms,
    login pages, dynamic content etc. Firewalls, SSL and locked-down servers are
    futile against web application hacking. Check your website for vulnerabilities
    to SQL injection, Cross site scripting and other web attacks before hackers do!
    Download Trial at:

    http://www.securityfocus.com/sponsor/pen-test_050831
    -------------------------------------------------------------------------------


  • Next message: Talisker: "RE: Scanning Class A network"

    Relevant Pages

    • Re: MDI design question
      ... but I still question why this should be part of the mainframe. ... embedded control programs, and I've never put communication control in the mainframe. ... >document will have unique device data, ...
      (microsoft.public.vc.mfc)
    • Re: The Mind of God
      ... and it is fairly safe there since the conscious computer controls the ... had the ability to control the mainframe conscious computer which is ... And in that episode the solution they arrive at is Gwendolyn. ...
      (sci.physics)
    • Re: how to organize several class and their instance in windows programming
      ... motion control and networking using MFC. ... Though I think the "design pattern" could solve my problem, ... I'd suggest that the mainframe is the WORST ...
      (microsoft.public.vc.mfc)
    • Re: how to organize several class and their instance in windows programming
      ... motion control and networking using MFC. ... Though I think the "design pattern" could solve my problem, but what I only want is to get a simple method or a belief understand. ... I'd suggest that the mainframe is the WORST ... For example, After Image processing, I would like to do some motion control... ...
      (microsoft.public.vc.mfc)
    • Re: The Mind of God
      ... is crash locator symbololgy there, with a skull, and a small disk ship ... had the ability to control the mainframe conscious computer which is ... projecting this reality. ...
      (sci.physics)

  • Quantcast